tile wisdom

Non-slip tiles: complete selection guide for 5 rooms

ELEGANZA - Bathroom with green marble look and light concrete look on wall and floor, Pamesa


By Osman Orman · Tile and technical specialist at Tegelmonsters

Anti-slip tiles are tiles with a measured friction that prevents you from slipping on a wet or greasy surface. This friction is defined by the R-value and the ABC classification.

The right choice starts with the space and the expected use, not with the appearance. A kitchen floor and a shower area each require a different value.

Summary
Anti-slip tiles are classified according to two standards. DIN 51130 specifies an R-value of R9 to R13 for use with footwear on a greasy floor, while DIN 51097 specifies an A, B, or C for bare feet on a wet floor. The Dutch standard NEN 7909 translates slip resistance into a friction coefficient. We link the correct value per room to a free sample request at tegelmonsters.nl/tegels and to an appointment in our showroom in Utrecht for architects and project managers.
Non-slip tiles in a wet shower area with R10 and B classification
A textured floor tile with R10 next to a smooth wall tile shows the difference in surface grip.

Operation & technology

What are non-slip tiles and how is slip resistance measured?

Anti-slip tiles have a measured friction that prevents slipping. The friction is defined by two standards: DIN 51130 gives an R-value of R9 to R13 for footwear, while DIN 51097 gives a classification of A, B, or C for bare feet. The R-value indicates how grippy the surface is, not how wear-resistant the tile is.

The skid resistance of a tile is a measurable property, not a matter of feel. A test laboratory determines the value using an incline test: a test subject walks across a surface that gradually becomes steeper, and the angle at which sliding begins determines the classification. The greater the angle, the more grip the surface offers under the chosen test conditions.

The R-value represents the friction of a tile under footwear. The abbreviation comes from the German word for friction, and the scale ranges from R9 to R13. Additionally, there is the coefficient of friction, a number that indicates how much resistance a shoe or foot encounters on the surface. Both numbers describe the same property based on a different measurement method.

For the architect or project manager, what matters most is that slip resistance is independent of wear resistance. A tile can score high on slip resistance and low on wear, or vice versa. The connection between these two properties and the choice per room is detailed in our selection guide for PEI and R-values ​​per room . You can find broader background on the measurement in the explanation of the anti-slip value of tiles.

DIN 51130

What do the R-values ​​R9 to R13 mean?

The R-values ​​are derived from DIN 51130. A test subject wearing safety shoes walks over an inclined surface with a thin film of oil. R9 corresponds to an angle of inclination of 6 to 10 degrees, R10 to 10 to 19, R11 to 19 to 27, R12 to 27 to 35, and R13 to more than 35 degrees. The higher the R-value, the more grip under greasy conditions.

The DIN 51130 method from 2014 intentionally uses strict test conditions. The oil film and work footwear simulate the most severe situation that can occur on a workplace. As a result, the R-values ​​are suitable for commercial and industrial zones, where grease, water, and spilled liquids make the surface slippery. The test subject walks forwards and backwards while the incline increases in steps.

The five classes form an ascending scale. R9 provides basic grip for dry indoor spaces, R10 adds grip for slightly wet zones, and from R11 onwards, the surface becomes noticeably more textured. R12 and R13 are suitable for heavy industrial environments with permanent contamination. Each step up the scale signifies a rougher surface, linking the choice to the expected cleaning regime of the space.

R-value, angle of inclination and typical space

The bar length scales with the angle of inclination from the inclination test. Scale according to DIN 51130 (2014).

R9
6 to 10 degrees, dry residential and office floor
R10
10 to 19 degrees, residential bathroom and public sanitary facilities
R11
19 to 27 degrees, terrace and commercial kitchen
R12
27 to 35 degrees, industrial kitchen and wet production
R13
Above 35 degrees, fat- and oil-rich industry
Source: DIN 51130 (2014), anti-slip classification for workspaces with increased risk of slipping.

The oil film inclination test is the basis on which manufacturers state their R-value on the technical data sheet. For the combination of skid resistance and wear resistance in a complete project specification, our selection guide for PEI per room offers the decision table that places this R-value choice in a broader context, without repeating the explanation of skid resistance here.

DIN 51097

Which A, B, or C classification applies to bare feet?

For barefoot use, DIN 51097 applies. The incline test uses soapy water instead of oil and a test subject without footwear. Class A corresponds to an incline angle of 12 degrees or more, class B to 18 degrees or more, and class C to 24 degrees or more. A is suitable for dry changing rooms, B for shower rooms and pool edges, and C for ramps and pool steps.

The ABC classification is a second measurement scale that runs parallel to the R-value. Because bare feet create grip differently than a shoe sole, and because soapy water lubricates differently than oil, the two standards are not mutually translatable. A tile with a good R-value does not automatically score a high ABC classification, and vice versa. Therefore, wet barefoot areas are always tested separately according to DIN 51097.

In practice, you often see a combined designation on a technical data sheet. For example, a residential bathroom tile is listed with R10 and B, a swimming pool coping with R11 and B, and a swimming pool ladder with C. The background for the choice of tiles for wet areas is explained in our explanation of non-slip in bathrooms and shower rooms , and for swimming pool projects in the guide to tiles for swimming pools.

Characteristic DIN 51130 (R-value) DIN 51097 (A/B/C)
Usage situation With footwear Barefoot
Test fluid Oil film Soapy water
Bowl R9 to R13 A, B and C
Threshold angle 6 to more than 35 degrees 12, 18 and 24 degrees
Typical zone Kitchen, terrace, workspace Shower, changing room, swimming pool

Per room

Which non-slip tiles belong to which room?

A workable minimum applies per room. Dry residential and office floors suffice with R9. A residential bathroom requires R10 with B, a terrace R11. Commercial kitchens and hospitality establishments go to R11 or R12, industrial wet rooms to R12 or R13. Swimming pool surrounds combine R11 with B, swimming pool steps receive C.

The function of the room determines the lower limit. A dry hallway poses a low risk of slipping, whereas a shower area is permanently wet and a kitchen floor is exposed to grease. Therefore, each zone has its own anti-slip value, sometimes an R-value, sometimes a combined designation with the ABC classification for bare feet. The choice follows the most severe scenario occurring in the room.

Space R-value Barefoot Point of attention
Living room, office R9 Not required Slippery, mopping is sufficient
Home bathroom R10 B Shower area sometimes R11
Terrace, balcony R11 Not required Also choose frost-resistant
Commercial kitchen R11 to R12 Not required Fat requires more grip
Pool edge R11 B Stairs and ramp to C
Industrial wet room R12 to R13 Not required Strict hygiene protocol

For the hospitality industry, in addition to slip resistance, the hygiene requirement comes into play, as kitchen and restaurant floors must comply with cleaning regulations. The combination of R-value, wear resistance, and HACCP is detailed in our guide for hospitality tiles . For outdoor spaces, in addition to R11 grip, frost resistance is also a factor, a consideration further elaborated in the guide for garden tiles .

Slip resistance is best felt. A data sheet lists the R-value, but a physical sample allows you to truly experience the surface. We send free samples of anti-slip tiles with R10, R11, and higher ratings, with the classification on the accompanying data sheet.

Request free samples Schedule a showroom appointment

Standards NL

How do NEN 7909 and the Building Decree relate to the R-value?

NEN 7909 translates slip resistance into a dynamic friction coefficient, a number representing the resistance between foot and surface. The guideline values ​​are a friction coefficient above 0,30 for dry zones, above 0,40 for wet zones, and above 0,45 for swimming pools. The Building Decree sets performance requirements for skid resistance but does not prescribe a fixed R-class.

The German DIN standards and the Dutch NEN standard describe the same property using a different measurement value. NEN 7909 specifies the requirement for slip resistance of walkable surfaces in a public space or workspace. It measures the dynamic friction coefficient, or the resistance between a measuring foot and the surface, both dry and wet. For wet applications, a guideline value above 0,40 applies, and for a swimming pool, above 0,45.

The Building Decree uses performance requirements instead of a fixed classification. For certain building functions, such as wet rooms in healthcare facilities, it sets a requirement for the slip resistance of the floor. The full text can be found on Bouwbesluit Online . A project team translates this performance requirement into a concrete DIN 51130 value in the specifications, supplemented with DIN 51097 for barefoot zones.

For the specifications writer, the practical route is clear. The NEN approach and the associated measurement method are described in NEN 7909. In the specification, you note the R-value for each room, the ABC classification where necessary, and the performance requirement from the Building Decree. The DIN designation on the manufacturer's data sheet is generally leading, as manufacturers test their product against it.

Maintenance & finishing

How does the finish affect maintenance and slip resistance?

The finish determines both grip and maintenance. A textured surface provides a higher R-value, but also collects fine dirt faster than a smooth surface. The same tile can achieve R9 in a matte version and R11 in a textured version. More grip therefore means a more intensive cleaning regime.

Slip resistance and maintenance are a trade-off that should be included together in the specifications. A rougher surface offers more grip in wet conditions, but the resulting microstructure also traps dirt and limescale. In a residential environment, a smooth R9 or R10 is therefore more practical, whereas a commercial kitchen requires a rougher R11 or R12 and maintains it with a mechanical cleaning regime. The choice is therefore not a matter of the highest rating.

The finish also contributes to the wear resistance and water absorption of the tile. An outdoor tile with an R11 rating is preferably porcelain stoneware, a fully ceramic, fired tile with a very dense body and a water absorption of less than 0,5 percent. This density makes the tile frost-resistant, which is just as important for outdoor use as slip resistance. The relationship with absorption is explained in our guide on the water absorption of ceramic tiles.

Advice from the specialists at Tegelmonsters
Include not only the R-value but also the finish in your specifications. Pamesa Ceramica from Spain, with a hydrogen-powered production line, supplies porcelain tiles with textured anti-slip finishes that achieve a different R-value depending on the version. Aleluia Ceramica from Portugal offers technical series with an anti-slip finish alongside the design-driven Color Art wall tiles. The same tile can score R9 in a matte finish and R11 in a textured version, so the finish belongs in the specification just as much as the R-value itself.

Sample package

How do you request a sample pack of non-slip tiles for your project?

A good sample pack contains 3 to 5 anti-slip tiles in the chosen R-value and, where necessary, the ABC classification, with a technical data sheet for each tile. With this set, you establish a traceable choice for each zone and feel the difference between a smooth and a textured finish before the tile is even installed in the project.

Physical assessment is more important for slip resistance than for most properties. Two tiles with the same R11 rating can feel different due to grain size and surface structure. The same applies to maintenance: a structured surface requires more cleaning than a smooth one. A sample set with three variants side by side makes this trade-off concrete, allowing you to choose the right balance between grip and maintenance for each zone.

Filter the assortment by zone. Select the application and filter our assortment by anti-slip value, color, and finish. The sample package will then arrive targeted, and you can bundle it per project in the Sample Folder.

Bathroom tiles Hospitality tiles Kitchen tiles Open the Sample Map

What project managers often tell us: the first filtering round takes place online, followed by a physical assessment in our showroom in Utrecht. That showroom is accessible to professionals by appointment only and offers samples in actual size. On the tiles page , you can filter for free by zone, size, and finish, after which our team sends the set with the correct anti-slip rating to the project or showroom address.

Frequently asked questions

What is the difference between DIN 51130 and DIN 51097?

DIN 51130 measures the skid resistance under footwear with an oil film and yields an R-value from R9 to R13. DIN 51097 measures the skid resistance for bare feet with soapy water and yields a classification of A, B, or C. The two standards use different test fluids and different footwear, so the results are not mutually translatable. Therefore, for a wet shower room, you often see a combined designation such as R10 and B.

What R-value do you need for a bathroom?

For a residential bathroom, R10 is the standard minimum, often combined with classification B from DIN 51097 for bare feet. This combination provides sufficient grip on a wet floor without the surface becoming too rough for daily maintenance. In the shower area itself, which is sloped, project teams sometimes choose R11. A public bathroom or wellness area aims for R11 with B or C.

Is a higher R-value always better?

No. A higher R-value means more surface texture and therefore more grip, but also more dirt absorption and a more intensive cleaning regime. R12 and R13 are suitable for commercial kitchens and wet production areas with a strict hygiene protocol. Such a surface is impractical in a residential environment. The correct anti-slip value is determined by the usage situation of the room, not by the highest number.

Which non-slip tiles do you use on a patio?

For a terrace or outdoor floor in a Dutch climate, R11 is the standard minimum, as the tile must maintain sufficient grip under rain and falling leaves. For outdoor stairs and ramps, the choice shifts towards R11 or R12. In addition to the R-value, frost resistance is also important: an outdoor tile is preferably porcelain stoneware with low water absorption in accordance with EN 14411 BIa.

Does the Building Decree mandate an R-value?

The Building Decree sets performance requirements for the slip resistance of floors in certain building functions, such as wet rooms in healthcare facilities, but does not prescribe an exact R-class. The Dutch standard NEN 7909 translates slip resistance into a dynamic friction coefficient. Project teams themselves translate this performance requirement into a concrete DIN 51130 value in the tender specifications, supplemented with DIN 51097 for barefoot zones.

Ready to set the anti-slip rating?

Request free samples and link the R-value, ABC classification, and finish to your project specifications in an hour.

Request free samples Schedule a showroom appointment

Sources

  1. DIN 51130 (2014). Testing of floor coverings, determination of anti-slip properties for work areas with increased slip risk. Deutsches Institut fuer Normung.
  2. DIN 51097 (1992). Testing of floor coverings, determination of the anti-slip property for barefoot areas. Deutsches Institut fuer Normung.
  3. NEN 7909. Slip resistance of walkable surfaces: requirement and determination method via dynamic friction coefficient. NEN.
  4. Building Decree 2012. Performance requirements for the slip resistance of floors in specific building functions. Central Government.
  5. EN 14411 / ISO 13006. Ceramic tiles: definitions, classification, characteristics and marking. European standard.
  6. Cersaie. International Exhibition of Ceramic Tile and Bathroom Furnishings, Bologna. Industry sheets with R and ABC designation.

Give a reaction